{"product_id":"te464g1","title":"TE464G1 Explosion-Proof Gas Imaging PTZ","description":"\u003cdiv class=\"pe-content\"\u003e\n\u003csection id=\"capabilities\" class=\"pe-block\"\u003e\u003cp class=\"pe-eyebrow\"\u003eWHAT THIS MODEL DOES\u003c\/p\u003e\n\u003ch2\u003eGas and temperature monitoring from a fixed PTZ\u003c\/h2\u003e\n\u003cdiv class=\"pe-feature-grid\"\u003e\n\u003carticle\u003e\u003ch3\u003ePatrol selected areas\u003c\/h3\u003e\n\u003cp\u003eContinuous pan, presets and patrol modes support repeated observation of inspection zones.\u003c\/p\u003e\u003c\/article\u003e\n\u003carticle\u003e\u003ch3\u003eConnect to a monitoring system\u003c\/h3\u003e\n\u003cp\u003eModbus TCP and ONVIF are listed for integration alongside temperature analysis and alarm functions.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection class=\"pe-block pe-tinted\"\u003e\u003cp class=\"pe-eyebrow\"\u003eGAS-SPECIFIC SELECTION\u003c\/p\u003e\n\u003ch2\u003eTE464G1 gas compatibility\u003c\/h2\u003e\n\u003cdl class=\"pe-spec-facts\"\u003e\n\u003cdiv\u003e\n\u003cdt\u003eInspection format\u003c\/dt\u003e\n\u003cdd\u003eFixed installation with pan and tilt\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eTarget gases\u003c\/dt\u003e\n\u003cdd\u003eMethane (CH₄), sulfur dioxide (SO₂), R-134a and R-152a are listed for TE464G1.\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdt\u003eSpectral response\u003c\/dt\u003e\n\u003cdd\u003e7–8.5 μm\u003c\/dd\u003e\n\u003c\/div\u003e\n\u003c\/dl\u003e\n\u003cp\u003eGas visibility and alarm performance must be assessed for the intended site. Confirm the supplied housing, approvals and integration requirements.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection id=\"specifications\" class=\"pe-block\"\u003e\u003cp class=\"pe-eyebrow\"\u003eTECHNICAL REFERENCE\u003c\/p\u003e\n\u003ch2\u003eTE464G1 specifications\u003c\/h2\u003e\n\u003cp class=\"pe-note\"\u003eManufacturer reference specifications. Options and supplied configuration are identified in your quotation.\u003c\/p\u003e\n\u003cdiv class=\"pe-table-wrap\"\u003e\u003ctable\u003e\n\u003ccaption\u003eImaging \u0026amp; optics\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetector Type\u003c\/th\u003e\n\u003ctd\u003eVOx uncooled focal plane detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpectral Band\u003c\/th\u003e\n\u003ctd\u003e7~8.5μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal Sensitivity\u003c\/th\u003e\n\u003ctd\u003e≤20mK(@25°C,F#1.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInfrared Resolution\u003c\/th\u003e\n\u003ctd\u003e640×512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePixel Pitch\u003c\/th\u003e\n\u003ctd\u003e12μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIFOV\u003c\/th\u003e\n\u003ctd\u003e0.48mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"pe-table-wrap\"\u003e\u003ctable\u003e\n\u003ccaption\u003eMeasurement \u0026amp; analysis\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd\u003e-20℃~+550℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Accuracy\u003c\/th\u003e\n\u003ctd\u003e±2°C or ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Analysis\u003c\/th\u003e\n\u003ctd\u003eSupports global, point, line, and area temperature measurement rules as well as alarm linkage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"pe-table-wrap\"\u003e\u003ctable\u003e\n\u003ccaption\u003eRecording \u0026amp; integration\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunication Interface\u003c\/th\u003e\n\u003ctd\u003e1 RJ45 10M\/100M adaptive Ethernet port; 1-channel RS485 interface, supporting Pelco protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePalettes\u003c\/th\u003e\n\u003ctd\u003eBlack-hot\/White-hot\/Rainbow\/Other palettes optional (20 modes in total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"pe-table-wrap\"\u003e\u003ctable\u003e\n\u003ccaption\u003eMechanical, power \u0026amp; environment\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e85V～260V AC\/24V DC 3A (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress Protection Rating\u003c\/th\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e≤100W (thermostat activated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e436×296×406 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e27kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature and Humidity\u003c\/th\u003e\n\u003ctd\u003e-40°C～+60°C; \u0026lt;90%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"documents\" class=\"pe-block pe-tinted\"\u003e\u003cp class=\"pe-eyebrow\"\u003eTECHNICAL DOCUMENTS\u003c\/p\u003e\n\u003ch2\u003eDownloads \u0026amp; selection resources\u003c\/h2\u003e\n\u003cdiv class=\"pe-documents\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/1043\/9083\/files\/phoebus-link-te464g1-selection-brief-v1.pdf?v=1793235470\" target=\"_blank\" rel=\"noopener\"\u003eTE464G1 · Phoebus Link selection brief \u003cspan\u003ePDF ↗\u003c\/span\u003e\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.raythink-tech.com\/wp-content\/uploads\/2026\/02\/Raythink_TE464G1_Product-Brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTE464G1 product brochure \u003cspan\u003eManufacturer PDF ↗\u003c\/span\u003e\u003c\/a\u003e\n\u003ca href=\"\/pages\/downloads?model=TE464G1\"\u003eBrowse TE464G1 resources \u003cspan\u003eOpen ↗\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"selection\" class=\"pe-block\"\u003e\u003cp class=\"pe-eyebrow\"\u003ePLAN THE CONFIGURATION\u003c\/p\u003e\n\u003ch2\u003eSpecify TE464G1 for your project\u003c\/h2\u003e\n\u003cp\u003eSpecify the gas or mixture, expected concentration, viewing distance and site conditions. Confirm detection suitability and any quantitative output for the selected configuration. A temperature sensitivity figure is not a gas detection limit. For hazardous locations, request the certificate and installation conditions for the exact supplied assembly.\u003c\/p\u003e\n\u003cdiv class=\"pe-brief\"\u003e\n\u003ch3\u003eInclude in your inquiry\u003c\/h3\u003e\n\u003cp\u003eTarget gas or mixture, expected concentration, viewing distance, site conditions and handheld or fixed installation.\u003c\/p\u003e\n\u003cp\u003eCompany, destination country, estimated quantity and target procurement date.\u003c\/p\u003e\n\u003ca class=\"pe-cta\" href=\"\/pages\/request-a-quote?model=TE464G1\"\u003eRequest a TE464G1 quote ↗\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection id=\"questions\" class=\"pe-block\"\u003e\u003ch2\u003eQuestions about TE464G1\u003c\/h2\u003e\n\u003cdetails class=\"pe-faq\"\u003e\u003csummary\u003eDoes optical gas imaging also provide gas concentration?\u003c\/summary\u003e\u003cp\u003eGas visualization and quantitative gas measurement are different capabilities. Confirm the exact gas, supported output, calibration and validation conditions for the quoted configuration; NETD is not a gas detection limit.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"pe-faq\"\u003e\u003csummary\u003eWhich documents are available for TE464G1?\u003c\/summary\u003e\u003cp\u003eUse the model-specific resources above for available brochures and the Phoebus Link selection brief. Ask for a current datasheet covering the exact lens, interface and options you intend to order.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"pe-faq\"\u003e\u003csummary\u003eWho handles my quotation and order?\u003c\/summary\u003e\u003cp\u003ePhoebus Link is your contact for product selection, quotations and order coordination. The equipment brand and full model are identified in the written quotation.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails class=\"pe-faq\"\u003e\u003csummary\u003eHow are delivery, warranty and returns confirmed?\u003c\/summary\u003e\u003cp\u003eFor B2B purchases, delivery timing, warranty duration, return or exchange conditions and related costs are confirmed in writing for each order. Obtain after-sales approval before returning equipment.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/section\u003e\n\u003csection class=\"pe-block\"\u003e\u003cp class=\"pe-eyebrow\"\u003eCONTINUE YOUR SELECTION\u003c\/p\u003e\n\u003ch2\u003eRelated gas imaging\u003c\/h2\u003e\n\u003cdiv class=\"pe-related\"\u003e\n\u003ca href=\"\/products\/te464g\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/1043\/9083\/files\/te464g-01.jpg?v=1793106392\u0026amp;width=440\" alt=\"TE464G Gas Imaging Camera\" width=\"440\" height=\"330\" loading=\"lazy\"\u003e\u003cstrong\u003eTE464G\u003c\/strong\u003e\u003cspan\u003eFixed optical gas imaging\u003c\/span\u003e\u003c\/a\u003e\n\u003ca href=\"\/products\/photon-c330b\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/1043\/9083\/files\/photon-c330b-01.jpg?v=1793106015\u0026amp;width=440\" alt=\"Photon C330B Cooled VOCs Gas Detection Thermal Camera\" width=\"440\" height=\"330\" loading=\"lazy\"\u003e\u003cstrong\u003ePhoton C330B\u003c\/strong\u003e\u003cspan\u003eCooled gas-imaging component\u003c\/span\u003e\u003c\/a\u003e\n\u003ca href=\"\/products\/rg600c\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/1043\/9083\/files\/rg600c-01.jpg?v=1793106340\u0026amp;width=440\" alt=\"RG600C Gas Imaging Camera\" width=\"440\" height=\"330\" loading=\"lazy\"\u003e\u003cstrong\u003eRG600C\u003c\/strong\u003e\u003cspan\u003eHandheld optical gas imaging\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Raythink","offers":[{"title":"Default Title","offer_id":48424590508203,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/1043\/9083\/files\/te464g1-01.jpg?v=1793105702","url":"https:\/\/phoebuslink.com\/products\/te464g1","provider":"Phoebus Link","version":"1.0","type":"link"}